logo
Nachricht senden

High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22

1
MOQ
High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22
Eigenschaften Galerie Produkt-Beschreibung Fordern Sie ein Zitat
Eigenschaften
Technische Daten
Faserkerndurchmesser: 1200μm
Paketgröße: 25X20X1 cm
Anschlusstyp: SMA905, FC
Wellenlängenbereich: 350 bis 2500 nm
Faser-Material: Quarz / Polyimid
Optionen für den Kerndurchmesser: 200 μm, 300 μm, 400 μm, 600 μm, 800 μm, 1000 μm
Länge: 3m
Numerische Blende: 0,37
Silikonrohr: ja/nein
Beschichtungsmaterial: ETFE
Leistungsschwelle: 1 GW/cm² (gepulst), 2 MW/cm² (kontinuierlich)
Verkleidungsmaterial: Hartes Polymer
Biegerradius: Klein
Zugfestigkeit: Hoch
Kern/Mantel-Verhältnis: 1.1 bis 1.2
Hervorheben:

High NA (0.37) Fiber Optic Patch Cord

,

Compatible with WiFi 3G Models High Power Laser Cable

,

IR1200/1320-1600AC-22 Medical Fiber Probe

Grundinformation
Herkunftsort: Guangdong, China
Markenname: Hicorpwell
Modellnummer: IR1200/1320-1600AC-22 und IR1200/1320-1700HT-22
Zahlung und Versand AGB
Produkt-Beschreibung
Special Large Core Fiber Bare Fiber 600/660um 800/880um Compatible WiFi 3G Models IR1200/1320-1600AC-22 IR1200/1320-1700HT-22
Medical Fiber Probe Description
High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 0 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 1

Special medical fiber available in a large range of diameters from 200µm to 1500µm HCW fibers.

A medical fiber probe is a length of optical fiber protected by a coating or jacket with two specifically prepared ends. One end is typically equipped with a connector interfacing the laser, while the other (distal) end is cleaved, polished, or may feature a special design (angle, side-fire, sphere, protective glass, etc.).

Selecting the appropriate fiber requires consideration of:

  • Laser source specifications: Wavelengths, power level, spot size, input and output NA
  • Design requirements: Maximum external diameter, length, specific design, bend radius
  • Environmental factors: Temperature, chemical exposure, biocompatibility, sterilization method
High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 2 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 3 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 4 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 5
Hicorpwell Special Large Core Diameter Fibers

These fibers feature a silica core, hard polymer cladding, and ETFE coating. Their large core diameter and high NA (0.37) provide efficient coupling to laser sources. While HCW fibers can handle high power, all-silica fibers are better suited for high-power applications.

The polymer cladding construction offers high tensile strength, excellent flexibility, and small bend radius for precise placement in the patient's body. This design is cost-effective, allowing use of low-cost devices and connectors ("One Shot SMA") with easy termination procedures for disposable probes.

Silica/Silica Fibers

Key features: Large core, 0.22 NA, high power capability, polyimide coating option

Medical applications using fiber optic delivery with high-power lasers (Nd:YAG, diode, Ho:YAG) for tissue alteration or vaporization are increasing. The laser power damage threshold of pure silica is approximately 1 GW/cm² for pulsed lasers and 2 MW/cm² for continuous operation.

Achieving high power transmission requires proper beam focusing into the fiber core. Poor alignment, focus, or spot quality can quickly damage the optical fiber and connector, making fiber selection critical.

High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 6 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 7
Technical Specifications
Parameter Specification
Connector SMA905 / FC
Core [μm] 200, 300, 400, 600, 800, 1000
Length [m] 3
Silicon tube Yes / No
Fiber Material Quartz / Polyimide
Connector type SMA905, FC
Wavelength range 350-2500nm
High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 8
Advantages of Hicorpwell Silica Fibers

All-silica fibers improve power handling and wavelength range compared to Hicorpwell fibers. For maximum power transmission, the beam must be properly focused into the fiber core. While power levels continue to increase, some laser energy may enter the cladding. With Hicorpwell construction, polymer cladding can burn and destroy the probe. In contrast, all-silica fibers with higher core-to-clad ratio (1.1 to 1.2) can accept some energy in the cladding without damage. For optimal performance, the spot diameter should fill no more than 2/3 of the fiber's core.

High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 9 High Power Laser Cable with High NA (0.37) for Medical Applications Compatible with WiFi 3G Models IR1200/1320-1600AC-22 10
Product Variants
Product Code Description
6149 MMF-IRVIS-50/125-0.25-L 0.25mm OD coated, 50/125μ multimode Gradient Index IRVIS fiber
3715 MMF-IRVIS-62.5/125-0.245-L 0.24mm OD, 62.5/125um IRVIS GI MM fiber
17017 MMF-IRVIS-100/140-0.25-L 0.25mm OD coated, 100/140μ multimode Gradient Index IRVIS fiber
Frequently Asked Questions
Q1: Are you a trading company or manufacturer?
A: We are factory verified by TUV.
Q2: What is your delivery time?
A: Generally, sample: 3~5 working days. Formal order: 7-10 working days.
Q3: Do you provide OEM service?
A: Yes, we can print your logo or label on the products or on the box.
Q4: Can you provide free samples?
A: Some low-value samples can be free, but you need to pay for shipping.
Q5: How do you guarantee quality?
A: With our quality management system, all products are 100% tested before shipment.
Q6: What are your payment terms?
A: We accept T/T, Western Union, MoneyGram, PayPal. Samples: 100% payment. Formal orders: 30% deposit, 70% balance before shipment.

For more information, contact us for details and competitive pricing. We welcome all inquiries and look forward to successful cooperation.

Empfohlene Produkte
Nehmen Sie Kontakt mit uns auf
Ansprechpartner : Mrs. Yvone Si
Telefon : 86-13480892975
Faxen : 86-755-23036652
Zeichen übrig(20/3000)